Location -> Electrode pen
Type:Precision Conductivity,TDS,Salinity Meter
Illustrate:*Meter factory reset function: users can use this function to reset the meter to the factory default and data log for convenient operation
Precision Conductivity/TDS/Salinity Meter
Main Features
*Microprocessor-based meter, high accuracy, good repetition
*Self-diagnostic for easy trouble-shooting
*Meter factory reset function: users can use this function to reset the meter to the factory default and data log for convenient operation
*3 set buffer selection–NIST, USA, DIN
*1-3 points automatic push-button calibration
*Electrode slope display for easy judgment of electrode performance
*Selectable automatic/manual temperature compensation
*Stability and average function for optimized results
*Auto-sleep function for Benchtop meter
*Auto-off conserves energy and lengthens battery lifespan
(Portable Meter)
*Low battery indicator: when battery icon lights up, battery power is low. Replace batteries with fresh ones as soon as possible.
*Store and output data function: the meter can store up to 500 sets data. Data can be sent to computer via USB link.
Models and Specifications
Portable Conductivity/TDS/Saliniity Meter Selection Guide
Main Features
*Microprocessor-based meter, high accuracy, good repetition
*Self-diagnostic for easy trouble-shooting
*Meter factory reset function: users can use this function to reset the meter to the factory default and data log for convenient operation
*3 set buffer selection–NIST, USA, DIN
*1-3 points automatic push-button calibration
*Electrode slope display for easy judgment of electrode performance
*Selectable automatic/manual temperature compensation
*Stability and average function for optimized results
*Auto-sleep function for Benchtop meter
*Auto-off conserves energy and lengthens battery lifespan
(Portable Meter)
*Low battery indicator: when battery icon lights up, battery power is low. Replace batteries with fresh ones as soon as possible.
*Store and output data function: the meter can store up to 500 sets data. Data can be sent to computer via USB link.
| Model | Description | Configuration | Application Field |
|
CX-RCB 6000-01 |
Precision Benchtop COND/TDS Meter |
benchtop COND/TDS meter (RCB6000) swing arm electrode stand (H-200) glass conductivity electrode with ATC (0301W) |
Measuring Cond / TDS for surface water, or regular simple water, not pure water |
|
CX-RCB 6000-02 |
Precision Benchtop COND/TDS For Pure Water |
benchtop COND/TDS meter (RCB6000) swing arm electrode stand (H-200) glass conductivity electrode with ATC (0302W) |
Measuring Cond / TDS for pure water, such as medical, electricity or chemical industries |
|
CX-RCB 6000-03 |
Precision Benchtop Salinity Meter |
benchtop Salinity meter (RCB6000) swing arm electrode stand (H-200) glass conductivity electrode (0303) stainless temperature electrode (T-10) |
Measuring salinity for solution |
|
CX-RCB 6000-10 |
Precision Benchtop COND/TDS/Salinity Meter |
benchtop COND/TDS/Salinity meter (RCB6000) swing arm electrode stand (H-200) glass conductivity electrode (0300) glass conductivity electrode (0303) stainless temperature electrode (T-10) |
Measuring Cond / TDS / Salinity for surface water, or regular simple water, not pure water |
| Model | CX-RCB6000/CX-RCB600 |
| Cond Range |
0-19.99μS/cm / 20.00-199.9μS/cm / 200.0-1999μS/cm / 2.00-19.99mS/cm / 20.00-199.9mS/cm |
| Cond Accuracy | 1% FS |
| Cond Calibration Point | 3 points |
| TDS Range | 0.000-9.999mg/l / 10.00-99.99mg/l / 100.0-999.9mg/l / 1000-9999mg/l |
| Salinity Range | 0.0-80.0ppt |
| Salinity Solution | 0.1ppt |
| Temperature Range | 0.0-99.9C / 32-212F |
| Temperature Solution | 0.1C/0.1F |
| Temperature Accuracy | +/-0.5C/+/-0.9F |
| Temperature Compensation | 0.0-60.0 C Auto/Manual |
| Temperature Coefficient | 0.0-3.0% |
| Cell constant | 0.1,1.0,10 |
| Memory | 500sets |
| Ambient Temperature | 5-45C |
| Display |
Meter sleeps (Benchtop) or shuts off (Portable) automatically 15 minutes after last key is pressed |
| input | BNC,φ3.5mm sockets |
| output | USB |
| power |
9V DC adepter,500 mA 100/240V (Bench top) 4X1.5V“AAA”alkaline battery (Portable ) |
Portable Conductivity/TDS/Saliniity Meter Selection Guide
| Model | Description | Configuration | Application Field |
|
CX-RCB 600-01 |
Precision Portable COND/TDS Meter |
portable COND/TDS meter (RCB600) glass conductivity electrode with ATC (DJS-1W) |
Measuring Cond / TDS for surface water, or regular simple water, not pure water |
|
CX-RCB 600-02 |
Precision Portable COND/TDS For Pure Water |
portable COND/TDS meter (RCB600) glass conductivity electrode with ATC (0302W) |
Measuring Cond / TDS for pure water, such as medical, electricity or chemical industries |
|
CX-RCB 600-03 |
Precision Portable Salinity Meter |
portable Salinity meter (RCB600) glass conductivity electrode (0303 ) stainless temperature electrode (T-10) |
Measuring salinity for solution |
|
CX-RCB 600-10 |
Precision Portable COND/TDS/Salinity Meter |
portable COND/TDS/Salinity meter (RCB600) glass conductivity electrode (DJS-1) glass conductivity electrode (0303) stainless temperature electrode (T-10) |
Measuring Cond / TDS / Salinity for surface water, or regular simple water, not pure water |