Location -> Products -> Display Instrument -> Paperless Recorder
Type:CX-PR-ASR200 paperless recorder
Illustrate:Paperless Recorder is a smart multifunctional instrument it is good to use for Monitoring, Controlling, Recording and Transmitting remotely various processing parameters
CX-PR-ASR200 Paperless Recorder
Main Features
Color Paperless Recorder, in design, adopting the consideration of computer architecture: in hardware, using TFT LCD display screen, new-type micro-processor with internal Flash ROM, possessing the large data storage capacities, as well as large size Liquid Crystal Display Panel ; In software, introducing the consideration of English/Chinese Windows Architecture, using data compression technology. Sub-Computerized structure, obviously embodying the great advantage of micro-process instrumentation. The Multi Function Color Paperless Recorder successfully actualizes, built in as small as 288x288x240 mm box, multi-channel data detection, displaying multi data, pictures, characters and curves in the single-screen/divided-screen, and including large capacity recording data storage.
Input Signal
| Input type | Input sort | Mode | Measuring range |
| Analog quantity | Voltage VDC | 0~20mV | -9999~99999 |
| 0~100mV | -9999~99999 | ||
| 0~5V | -9999~99999 | ||
| 1~5V | -9999~99999 | ||
| Current IDC | 0~10mA | -9999~99999 | |
| 4~20mA | -9999~99999 | ||
| Thermocouple TC | S | -50.0~1769.0C | |
| B | -50.0~1820.0C | ||
| K | -50.0~1372.0C | ||
| E | -50.0~1000.0C | ||
| J | -50.0~1200.0C | ||
| T | -199.90~320.00C | ||
| Wre 3-25 | 0.0~2300.0C | ||
| Thermal resistance RTD | Pt100 | -200.0~850.0C | |
| Cu50 | -50.00~150.00C | ||
| Switching value | DI | Connection point input | Connection point:on/off |
| DCV input(TTL) |
OFF:2.4V below ON:2.4V above |
||
| Pulse value | Rectangle /sine/triangle | Amplitude≥4V | Frequency 0-15KHz |
Output Signal
| Output type | Input sort | Model | Measuring range | Comment |
| Analog quantity | Voltage VDC | 0~5V | -9999~99999 | Load≤750 Ω |
| 1~5V | -9999~99999 | Load≤750 Ω | ||
| Current IDC | 0~10mA | -9999~99999 | Load≤750 Ω | |
| 4~20mA | -9999~99999 | Load≤750 Ω | ||
| Switching value | Relay touch spot | AC 220V/3A | ||
| DC 24V/5A | -50.0~1820.0C | |||
| SCR output | 40V/0.5A | |||
| SSR output | 5~ 24V/0.05A | |||
| Feed | DC 24V/60mA |
Main Parameters
| Accuracy | 0.5 %FS±1 digit or 0.2%FS±1 digit |
| Small-signal removal | 0 — 25.5%FS |
| Measuring range | -9999 — 99999 digit |
| Sampling Period | 0.25 second |
| Interrecord Time | Between 1 second and 4 minutes take a second as a unit there are 240 ways for you to choose |
| Display mode | High resolution, brightness adjustable, wide view angle and bright TFT color LCD (320x234) with saving screen (5.6” for ASR100 series) |
| Parameters setting | By Key nods or upper linking computer setting. Security lock function is available. |
| Alarm | 4 alarm points per channel are available. Upper/lower alarm, rate-of-change and differential limit; Alarm output delay, alarm delay high to low, external connection sound available, max 12 latest alarm messages are saved per channel. |
| Communication port | RS-232,RS-485: Buad rate 1200 – 115200 bps |
| Printer | TPμP-A40 micro printer is recommended. |
Last: CX-PR-ASR100 color paperless r.. Next:CX-PR-VPR130-RG paperless recor..