Location -> Liquid level
Type:FWD-L Series magnetostrictive displacement sensor
Illustrate: FWD-LSeriesMagnetostrictivedisplacementsensortoprovideavarietyofoutputmodes,Includinganalogvoltageandcurrent,RS485andotherdigitalcontent.Digitaloutputsignalcanprovideanumberofpositionandvelocityoutput.Detailedmulti-outputmodel,toprovidecustomersw..

FWD-L Series Magnetostrictive displacement sensor to provide a variety of output modes, Including analog voltage and current, RS485 and other digital content. Digital output signal can provide a number of position and velocity output. Detailed multi-output model, to provide customers with more choices.
FWD-L Series Magnetostrictive displacement sensor can provide different installation methods, divided into two kinds of built-in and external. Built-in tank for the built-in installation,Measuring rod for the 304L stainless steel pressure pipe。As a result of the module assembly, the scene is very simple to replace sensitive components,No need to withdraw fully hydraulic, quick process, greatly reduce the shutdown time. External Connector can use the form placed in the external moving parts,With the installation of flexible features.
Main features:
Non-contact, Never worn; High-resolution, high precision, high stability, high reliability, fast response time, long working life; sensors without re-calibration, are not regularly maintained.Application:
◆Servo gas, hydraulic cylinder piston position feedback or preset
◆ position feedback or pre-grinding machine
◆ Casting and Forging machine displacement control
◆ positioning and monitoring of injection molding
◆ Wood processing position control
◆ turbine gas block valve opening detection and control
◆ Turbine Guide Ye Kai-degree detection and control
◆ other mechanical positioning and displacement detection
Parameters:
| Measurements | Position or velocity |
| Measuringrange (mm) | 80-5000(Can be customized according to user) |
| Nonlinearity (±%FS) | 0.05%FS;Range 200mm maximum error of the following 0.1mm |
| Repeatability error | ≤0.002%FS |
| Resolution | ≤0.02mm |
| Sluggish | ≤0.002%FS |
| Temperature | ±50ppm/℃ |
| Operating Voltage | +11VDC~+36VDC |
| Current: | ≤10mA(Increase or decrease with changes in range) |
| Operating Temperature | T1:-25~+55℃, T2:-40~+85℃, T3:-50~+125℃ |
| Load Characteristics: | Maximum voltage output current output load resistance 3kΩ 600Ω maximum load resistance |
| Output Type | 0~5V、1~5V 、0~10V、4~20mADC、RS485 |
| Working pressure | 34MPa |
| Electronic storage enclosure material | Aluminum (user can specify custom 304 stainless steel special structure) |
| Measuring rod material | OCr18Ni9(304)、316L Stainless steel (special custom) |
| Connection Type | M18x1.5、M20x1.5、3/4-16UNF(british system) |
| Lead way |
1、 Straight out of cable (standard length: 3m, can also be customized according to user requirements) 2、 Air Plug (does not apply to flameproof products) 3、 Terminal Blocks |
| Enclosure protection class | IP67 |
2. FWD-F series Magnetostrictive liquid level sensor
FWD-F series Magnetostrictive liquid level sensor Variety of output modes, including analog voltage and current, RS485 and other digital content. Digital output signal can provide multiple locations and temperature output. Detailed multi-output model, to provide customers with more choices.FWD-F Series non-contact magnetostrictive liquid level sensor, never worn. High resolution, high accuracy, high stability, high reliability, fast response time, work and long lifetime. Without re-calibration of sensors, also without regular maintenance. FWD-F Series magnetostrictive liquid level sensor of explosion-proof products in strict accordance with GB3836.1-2000 "Electrical apparatus for explosive gas atmospheres General requirements", GB3836.2-2000 "Electrical apparatus for explosive gas atmospheres Flameproof" d " "GB3836.4-2000" Electrical apparatus for explosive gas atmospheres Intrinsic safety "i" "requirements of the development, design, manufacture. And achieved national apparatus explosion safety supervision and inspection station certificate issued by the explosion. Explosion-proof mark: EXd Ⅱ BT5. Intrinsically Safe logo:EXiaⅡCT6。
FWD-F series Magnetostrictive liquid level sensor can be applied:
◆ level measurement and control industrial field
◆ Oil Tank Level Measurement
◆ Chemical Process Level Control
◆ pharmaceutical tank level control
◆ Food & Beverage tank control
◆ Dam Water Level Monitoring
◆ water and wastewater treatment
Parameters:
| Measurements | Position or velocity |
| Measuringrange (mm) | 300-5000(Can be customized according to user) |
| Nonlinearity (±%FS) | 0.05%FS;Maximum error is 0.5mm measuring range 1000mm |
| Repeatability error | ≤0.002%FS |
| Resolution | ≤0.02mm |
| Sluggish | ≤0.002%FS |
| Temperature | ±50ppm/℃ |
| Operating Voltage | +11VDC~+36VDC |
| Current: | ≤8mA(Increase or decrease with changes in range) |
| Operating Temperature | T1:-25~+55℃, T2:-40~+85℃, T3:-50~+125℃ |
| Load Characteristics: |
Voltage output, maximum load resistance 3kΩ 电流输出时最大负载电阻600Ω |
| Output Type | 0~5V、1~5V 、0~10V、4~20mADC、RS485 |
| Working pressure | 10MPa |
| Electronic storage enclosure material | Aluminum (user can specify custom 304 stainless steel special structure) |
| Measuring rod material | OCr18Ni9(304)、316L Stainless steel (special custom) |
| Connection Type | M18x1.5、M20x1.5、3/4-16UNF(british system) |
| Lead way |
4、 Straight out of cable (standard length: 3m, can also be customized according to user requirements) 5、 Air Plug (does not apply to flameproof products) Terminal Blocks |
| Enclosure protection class | IP67 |