Asphalt Metering Pump: A Real Case

A research institute needed a metering pump for small amounts of asphalt — with flow display. Here's how we solved it.

The Problem

  • Flow: 80–120 L/H

  • Temperature: 90–150°C

  • Viscosity: 300–600 mm²/s

  • Accuracy: ±3%

  • Display: real-time L/H

Key issue: Asphalt cools and solidifies after each experiment. A flow meter won't work — it clogs and is hard to clean.

Our Solution: J2H120/1.0 Plunger Metering Pump

  • Type: Plunger metering pump

  • Flow: 120 L/H

  • Pressure: 1.0 MPa

  • Inlet/Outlet: DN15 flange

  • Pump head: Full jacket heating

  • Motor: 0.75KW-4

  • Material: 304 stainless steel

  • Power: AC380V 50HZ 3PH

Why it works:

✅ High accuracy — up to ±1%

✅ Jacket heating — keeps asphalt hot, no solidification

✅ No flow meter — display from pump parameters

✅ 304 stainless steel — easy to clean

✅ Real-time L/H display

Why Not Other Pumps?

  • Gear pump ❌ — solidifies, gears jam

  • Screw pump ⚠️ — still needs flow meter

  • Diaphragm pump ⚠️ — damaged by heat

  • Plunger metering pump ✅ — precise, heatable, no flow meter

Conclusion

For high-temperature, high-viscosity, solidifying media — choose a plunger metering pump with jacket heating.

CIXIFM specializes in industrial and chemical metering pumps. Contact us for a free solution.


📩 Contact

CIXIFM Winny

  • Email: sales01@cxflowmeter.com

  • WhatsApp: +86 18049841995

Last:没有了 Next:Pump Selection for Honey: Why S..

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

关闭