Location -> News
News
Asphalt Metering Pump: A Real Case
A research institute needed a metering pump for small amounts of asphalt — with flow display. Here's how we solved it.
The Problem
-
Flow: 80–120 L/H
-
Temperature: 90–150°C
-
Viscosity: 300–600 mm²/s
-
Accuracy: ±3%
-
Display: real-time L/H
Key issue: Asphalt cools and solidifies after each experiment. A flow meter won't work — it clogs and is hard to clean.
Our Solution: J2H120/1.0 Plunger Metering Pump
-
Type: Plunger metering pump
-
Flow: 120 L/H
-
Pressure: 1.0 MPa
-
Inlet/Outlet: DN15 flange
-
Pump head: Full jacket heating
-
Motor: 0.75KW-4
-
Material: 304 stainless steel
-
Power: AC380V 50HZ 3PH
Why it works:
✅ High accuracy — up to ±1%
✅ Jacket heating — keeps asphalt hot, no solidification
✅ No flow meter — display from pump parameters
✅ 304 stainless steel — easy to clean
✅ Real-time L/H display
Why Not Other Pumps?
-
Gear pump ❌ — solidifies, gears jam
-
Screw pump ⚠️ — still needs flow meter
-
Diaphragm pump ⚠️ — damaged by heat
-
Plunger metering pump ✅ — precise, heatable, no flow meter
Conclusion
For high-temperature, high-viscosity, solidifying media — choose a plunger metering pump with jacket heating.
CIXIFM specializes in industrial and chemical metering pumps. Contact us for a free solution.
📩 Contact
CIXIFM Winny
-
Email: sales01@cxflowmeter.com
-
WhatsApp: +86 18049841995
Last:没有了 Next:Pump Selection for Honey: Why S..