Choosing flow measurement for a NOx generator test rig usually means a trade-off. A Venturi tube with a DP transmitter looks cheap up front, but piping changes, temperature/pressure compensation and commissioning add hidden cost. Premium Coriolis or imported thermal meters perform well, yet three units blow the budget.
A more pragmatic route: three thermal mass flow meters, one per zone, all with 316 SS wetted parts, 24 VDC supply and 4–20 mA output.
Zone A — Combustion Air (DN100 Insertion)
Blower suction side, 110.3 mm ID, 80–140 m³/h at 20°C, near atmospheric and slightly negative. Extremely low pressure loss required.
Recommended: DN100 insertion thermal mass flow meter, 316 SS. No pipe cutting, negligible pressure drop, far cheaper than inline at this diameter. Outputs mass flow directly, so no temperature/pressure compensation is needed — just one clean 4–20 mA signal to the PLC. Typical accuracy ±1–2% of reading.
Zone B — Heated Air (DN25 Inline, High-Temperature)
21 mm ID, 4.2–7.0 m³/h at 20°C up to 6.8–11.3 m³/h at 200°C. Normal max 200°C, absolute max 400°C.
Recommended: DN25 inline high-temperature thermal mass flow meter, 316 SS, split design. The 400°C limit is the binding constraint — standard sensors are rated below 200°C, so a high-temperature probe is mandatory. Split electronics keep the transmitter away from the hot pipe. State "sensor probe rated to 400°C" explicitly in the RFQ.
Zone C — Dutch Natural Gas (G-gas), DN15 Inline
15 mm ID, 7.3–12.2 m³/h at 20°C atmospheric, up to 200 mbar(g), methane-rich gas.
Recommended: DN15 inline thermal mass flow meter, 316 SS, flanged. Two hard requirements: Ex or intrinsically safe certification for flammable service, and calibration on the actual gas composition — thermal meters rely on specific heat and thermal conductivity, so an air-calibrated unit on natural gas carries significant error. Provide the typical G-gas composition (>85% methane) and require calibration to it.
A DN25 vortex meter was also considered, but at DN25 on gas it has weak signal at low flow and needs temperature/pressure compensation for mass flow. Thermal remains simpler if 7.3 m³/h gives adequate velocity in DN15.
Common Requirements
24 VDC; 4–20 mA proportional to mass flow or Nm³/h; accuracy ±1–2% of reading; SS316/316L wetted parts; very low pressure drop; CE with documentation; standard 4–20 mA PLC input. Economy thermal meters in DN15/DN25 inline typically fall in the low-thousands RMB range per unit; the DN100 insertion unit is somewhat higher.
Versus Venturi + DP
DP has an advantage in Zone B's 400°C service, but the Venturi must still withstand the temperature, and micro-differential measurement at a few mbar positive pressure has poor signal-to-noise. The three-thermal-meter approach wins on simplicity: independent mass flow output per meter, no compensation math, minimal PLC configuration.
Next step: send the RFQ to two or three domestic economy thermal meter suppliers, flagging Zone B's 400°C probe requirement and Zone C's G-gas calibration. Compare lead times and warranty, then award.